Advanced Propagator
| Field | Description |
|---|---|
| Minimum Propagation Time | Specify the minimum time that must elapse from the beginning of the segment until Astrogator will begin checking stopping conditions for satisfaction. |
| Maximum Propagation Time | Select to specify a maximum propagation time, after which the segment will end regardless of whether the stopping conditions have been satisfied. |
| Warning Message on Maximum Propagation Time | Select to have Astrogator issue a warning message if propagation is stopped by the Maximum Propagation Time parameter. |
| Duration and Epoch Stopping Conditions Override Max Prop Time | Select to have Astrogator ignore the Maximum Propagation Time if the segment contains an enabled Duration or Epoch Stopping Condition. |
| Stop Immediately for Initially Surpassed Epoch Stopping Conditions | Select to immediately stop propagation on a particular segment if the propagation begins beyond an active Epoch Stopping Condition. |