Description | Example | Return message | Group

Access

Calculate access intervals between two objects.

Syntax

Access <FromObjectPath> <ToObjectPath> [{AccessOptions}] [ForceRecompute]

Related commands

Description

The Access Connect command can be used to calculate access intervals between objects and control the display of access graphics. An access interval is the time period during which visibility between two objects is possible while meeting any constraints defined for either object.

An existing Access between the specified objects will be recomputed when the [ForceRecompute] parameter is specified. If the [ForceRecompute] parameter is not specified, an existing Access will be recomputed only if {AccessOptions] causes a setting of the existing Access to change.

Any number of the following {AccessOptions} can be included in the command:

{AccessOptions}Description
TimePeriod {Objects | {TimeInterval} | "<TimeIntervalList>"}Enter the time period to use as the access interval.

Specify Objects to use the object time periods as access intervals. If no TimePeriod option is entered this option is used.

For valid {TimeInterval} values see Time Options.

For valid "<TimeIntervalList>" specification see Component Specification.

MaxStepSize <Value>The MaxStepSize limits the amount of time that is allowed to elapse between sampling of the constraint functions during access computations. The value is entered in Connect time units and must be between 1.0e-5 and 315576000.0 seconds.

When this value is entered Step Size Control will be set to use a variable step to choose samples.

MinStepSize <Value>The MinStepSize limits the amount of time that is allowed to elapse between sampling of the constraint functions during access computations. The value is entered in Connect time units and must be between 1.0e-5 and 315576000.0 seconds.

When this value is entered Step Size Control will be set to use a variable step to choose samples.

ClockHost {1 | 2 | Base | Target}Access reports the transmission/reception times using time values associated with the designated clockhost. A value of 1 or Base specifies the first object as the clock host; a value of 2 or Target specifies the second object as the clock host.
Mode {Transpond | Transmit | Receive} The mode of signal transmission of the designated clock host, used in the apparent relative position computation used by Access. Transmit indicates that the clock host is transmitting; Receive indicates the clock host is receiving the signal. Both indicate that light time delay is considered. The value Transpond turns light time delay off (where distinctions between transmit and receive are no longer necessary).
AberrationType {Total | Annual | None}Sets the model of aberration to be used in access computations. None indicates that aberration is ignored; Annual indicates that only annual aberration is accounted for; Total indicates that the full aberration correction is to be applied.
TimeConvergence <Value>Sets the time tolerance used by the access algorithms for determining the start and stop time of access intervals. The event detection routine declares that an event is found when either the value of the access constraint converges to the desired value to within 8 digits or the time interval in which the event lies is within the time tolerance. <Value> is entered in Connect time units (1.0e-9 seconds <= t <= 1.0 seconds).

EventsBasedOnSamples must be set to Off for this value to have any effect.

LightTimeDelayConvergence <Value>Sets the time tolerance used by the access algorithms for computing the light time delay between objects, when light time delay effects are considered. The light time delay is found whenever a correction to the previous estimate is within the time tolerance. <Value> is entered in Connect time units (1.0e-9 seconds <= t <= 0.1 seconds).
EventsBasedOnSamples {On | Off}Turn EventsBasedOnSamples On to determine access intervals simply based on the samples without doing any extra sub-sampling.
AbsValueConvergence <Value>Set the criterion used for convergence for values near 0. <Value> must be between 1e-30 and 1e30

EventsBasedOnSamples must be set to Off for this value to have any effect.

RelValueConvergence <Value>An event is said to be detected when a constraint value's relative difference compared to the previous sample is within this tolerance. <Value> must be between 0.0 and 1.0

EventsBasedOnSamples must be set to Off for this value to have any effect.

FixedSampleStep <Value> Enter a step size value to control the step size used in Access sampling. <Value> is entered in Connect time units and must be between 1.0e-5 and 315576000.0 seconds.

When this value is entered Step Size Control will be set to use a fixed step to choose samples.

FixedStepTimeBound <Value> Enter a value to have the fixed sample steps calculated on a specific time boundary. <Value> is entered in Connect time units and is between 0.0 and 86400.0seconds.

When this value is entered Step Size Control will be set to use a fixed step to choose samples.

AutoAddTimeline {On | Off}Enter On to have the Access time intervals automatically added to the Timeline View when the Access is computed. The default for this value can be set with the AccessConfig command.
UpdateOnReference {On | Off}Enter Off to disable Access from automatically recomputing when a change occurs to an object that Access depends on. The default value for this property is On.

Graphics

The graphics options available for this command in previous versions have been deprecated in STK 9. These options will be maintained for backward compatibility only. To set Access graphics options use the Graphics SetAccessGfx command. The deprecated options are:

[{InheritFlag}] [{LineGfxState} {AnimGfxState} {StaticGfxState}]

Examples

To calculate access over the scenario time period:

Access */Satellite/Sat1 */Facility/Fac1 TimePeriod UseScenarioInterval

To calculate access between 0.0 and 30000.0 epoch secs:

SetUnits / EpochSec
Access */Satellite/Sat1 */Facility/Fac2 TimePeriod "0.0" "30000.0"

To calculate the periods of access between the ERS1 satellite and the Baikonur facility in the stkDemo scenario:

Access */Satellite/ERS1 */Facility/Baikonur

To calculate access over the scenario time period, using a maximum step size of 240 seconds:

Access */Satellite/Sat1 */Facility/Fac1 TimePeriod Scenario MaxStepSize 240.0

To calculate access over the specified time period, also specifying the fixed sample step size, time bound value:

setunits * epochsec
Access */Satellite/Satellite1 Facility/Facility1 TimePeriod "0.0" "1200.0" EventsBasedOnSamples On FixedSampleStep 2.0 FixedStepTimeBound 60.0 Mode Transpond

To calculate the access over Facility1's Sunlight Interval List:

Access */Facility/Facility1 */Satellite/Satellite1 TimePeriod "Facility/Facility1 LightingIntervals.Sunlight Interval List"

To calculate the access and add the resulting intervals to the Timeline View:

Access */Satellite/Satellite1 */Place/Place1 AutoAddTimeline On

Return message

This command returns a single message response. If no accesses can be determined, a "NoAccesses" message is returned.

Connect returns a message that includes the from object, the to object, the number of accesses and the start and stop time of all periods of access, as illustrated in the following example:
/Application/STK/Scenario/stkDemo/Satellite/ERS1 /Application/STK/Scenario/stkDemo/Facility/Baikonur 3 1 Nov 2000 00:10:43.56 1 Nov 2000 00:21:46.46 1 Nov 2000 01:47:12.15 1 Nov 2000 02:02:05.32 1 Nov 2000 03:27:37.56 1 Nov 2000 03:41:17.87

Group membership

This command belongs to the following group(s):

Object Tools

Version