Description | Example | Return message | Group

SetConstraint (EOIR)

Set an EOIR constraint for a sensor

Syntax

SetConstraint <SensorObjectPath> {ConstraintName} <Parameters>

Related commands

Description

Caution should be exercised when turning a constraint Off, in that any previously set constraint values may be lost. These cannot be recovered when the constraint is subsequently turned On.

You can use the SetConstraint command to turn EOIR constraints On and Off and also set values for the constraints. The following table lists valid values for {ConstraintName} as well as the parameters accepted for each. Only one constraint can be set with each SetConstraint command.

EOIR Constraints

The following constraints are valid for Sensor objects:

{ConstraintName}Parameters
EOIRSNR{Off | Min <Value1> [|] Max <Value2>} [ExcludeIntervals | IncludeIntervals], where <Value1> and <Value2> are between 1.0e-300 and 1.0e300.

Examples

To set minimum and maximum values for the EOIRSNR constraint:

SetConstraint */Satellite/Satellite1/Sensor/Sensor1 EOIRSNR Min 1.23 Max 1000

Return message

Group membership

This command belongs to the following group(s):

Sensors

Version

9.2.1