SEET Radiation Dose Depth
Computes the radiation dose over the requested time interval(s), using the step size to perform the numerical integration of dose rate with time. Valid for vehicles whose central body is earth.Available for these objects: LaunchVehicle, Missile, Satellite
Type: Time-varying data. Intended to be used only with elements from this same data provider.
Availability: Reports | Graphs
Data Provider Elements
Name | Dimension | Type | Description |
---|---|---|---|
Shielding thickness | RadiationShieldThickness | Real Number | The shielding thickness at which the dose was computed. |
Electron dose | RadiationDose | Real Number | The accumulated radiation dose due to electrons for the shielding thickness indicated, at the given time. The values next to Electron-Bremsstrahlung, Proton, and Combined doses are default values when computational mode and shielding thickness are unchanged. IRENE does not produce separate Electron-Bremsstrahlung dose values. They are included with normal Electron dose values. Valid when using NASA, IRENE, or CRRES models. |
Electron-Bremsstrahlung dose | RadiationDose | Real Number | The accumulated radiation dose due to Bremsstrahlung electrons, at the given time. The values next to Electron-Bremsstrahlung, Proton, and Combined doses are default values when computational mode and shielding thickness are unchanged. Valid when using NASA, IRENE, or CRRES models. |
Proton dose | RadiationDose | Real Number | The accumulated radiation dose due to protons for the shielding thickness indicated, at the given time. Valid when using NASA or CRRES models. |
Combined dose | RadiationDose | Real Number | The accumulated total radiation dose from all constituents, at the given time. |