Access Gaps
Reports intervals where access does not exist between the objects.Available for these objects: Access
Type: Interval data.
Availability: Reports | Graphs
Data Provider Elements
| Name | Dimension | Type | Description |
|---|---|---|---|
| Gap Number | Unitless | Integer | Counter of the gaps between access intervals. |
| Start Time | Date | Real Number or Text | Start time of an interval. |
| Stop Time | Date | Real Number or Text | Stop time of an interval. |
| Duration | Time | Real Number | The duration of the interval. |
| From Pass Number | Unitless | Text | The pass number of the From-object at the start of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
| To Pass Number | Unitless | Text | The pass number of the To-object at the start of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
| From Start Lat | Latitude | Real Number or Text | The detic latitude of the From-object at the start of the interval. |
| From Start Lon | Longitude | Real Number or Text | The detic longitude of the From-object at the start of the interval. |
| From Start Alt | Distance | Real Number | The detic altitude of the From-object at the start of the interval. |
| From Stop Lat | Latitude | Real Number or Text | The detic latitude of the From-object at the end of the interval. |
| From Stop Lon | Longitude | Real Number or Text | The detic longitude of the From-object at the end of the interval. |
| From Stop Alt | Distance | Real Number | The detic altitude of the From-object at the end of the interval. |
| To Start Lat | Latitude | Real Number or Text | The detic latitude of the To-object at the start of the interval. |
| To Start Lon | Longitude | Real Number or Text | The detic longitude of the To-object at the start of the interval. |
| To Start Alt | Distance | Real Number | The detic altitude of the To-object at the start of the interval. |
| To Stop Lat | Latitude | Real Number or Text | The detic latitude of the To-object at the end of the interval. |
| To Stop Lon | Longitude | Real Number or Text | The detic longitude of the To-object at the end of the interval. |
| To Stop Alt | Distance | Real Number | The detic altitude of the To-object at the end of the interval. |
| Start Constraint | Unitless | Text | The access constraint that determined the start time of the gap. |
| Stop Constraint | Unitless | Text | The access constraint that determined the stop time of the gap. |
| From Pass Number End | Unitless | Text | The pass number of the From-object at the end of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
| To Pass Number End | Unitless | Text | The pass number of the To-object at the end of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
| To Object | Unitless | Text | The class name and name of the To-object. |
| From Object | Unitless | Text | The class name and name of the From-object. |
| To Parent | Unitless | Text | The name of the parent of the To-object. If the object has no parent (other than the Scenario), then the value will be "No Parent". |
| From Parent | Unitless | Text | The name of the parent of the From-object. If the object has no parent (other than the Scenario), then the value will be "No Parent". |
| From Precision Pass Number | Unitless | Real Number or Text | The precision pass number of the From-object at the start of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
| To Precision Pass Number | Unitless | Real Number or Text | The precision pass number of the To-object at the start of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
| From Precision Pass Number End | Unitless | Real Number or Text | The precision pass number of the From-object at the end of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
| To Precision Pass Number End | Unitless | Real Number or Text | The precision pass number of the To-object at the end of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
| From Path Number | Unitless | Text | The path number of the From-object at the start of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
| To Path Number | Unitless | Text | The path number of the To-object at the start of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
| From Path Number End | Unitless | Text | The path number of the From-object at the end of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
| To Path Number End | Unitless | Text | The path number of the To-object at the end of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
| From Precision Path Number | Unitless | Real Number or Text | The precision path number of the From-object at the start of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
| To Precision Path Number | Unitless | Real Number or Text | The precision path number of the To-object at the start of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
| From Precision Path Number End | Unitless | Real Number or Text | The precision path number of the From-object at the end of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
| To Precision Path Number End | Unitless | Real Number or Text | The precision path number of the To-object at the end of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
| Start Constraint Definition | Unitless | Text | Reports out constraint-dependent parameters, if applicable, for the start constraint; otherwise, not applicable. |
| Stop Constraint Definition | Unitless | Text | Reports out constraint-dependent parameters, if applicable, for the stop constraint; otherwise, not applicable. |
| Start Constraint Definition with Units | Unitless | Text | Reports out constraint-dependent parameters, if applicable, for the start constraint, where the units for values are indicated; otherwise, not applicable. |
| Stop Constraint Definition with Units | Unitless | Text | Reports out constraint-dependent parameters, if applicable, for the stop constraint, where the units for values are indicated; otherwise, not applicable. |
| From Precision Pass Number Mid | Unitless | Real Number or Text | The precision pass number of the From-object at the mid-time of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
| To Precision Pass Number Mid | Unitless | Real Number or Text | The precision pass number of the To-object at the mid-time of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
| From Start UTM Zone | Unitless | Text | The UTM Zone character indicator for the detic subpoint of the From-object at the start of the interval. Available only when the central body is Earth. |
| From Start UTM Easting | Distance | Real Number | The easting value within the UTM zone for the detic subpoint of the From-object at the start of the interval. Available only when the central body is Earth. |
| From Start UTM Northing | Distance | Real Number | The northing value within the UTM zone for the detic subpoint of the From-object at the start of the interval. Available only when the central body is Earth. |
| From Start MGRS Cell | Unitless | Text | The MGRS (Military Grid Reference System) code for the cell area containing the detic subpoint of the From-object at the start of the interval. Available only when the central body is Earth. |
| From Stop UTM Zone | Unitless | Text | The UTM Zone character indicator for the detic subpoint of the From-object at the end of the interval. Available only when the central body is Earth. |
| From Stop UTM Easting | Distance | Real Number | The easting value within the UTM zone for the detic subpoint of the From-object at the end of the interval. Available only when the central body is Earth. |
| From Stop UTM Northing | Distance | Real Number | The northing value within the UTM zone for the detic subpoint of the From-object at the end of the interval. Available only when the central body is Earth. |
| From Stop MGRS Cell | Unitless | Text | The MGRS (Military Grid Reference System) code for the cell area containing the detic subpoint of the From-object at the end of the interval. Available only when the central body is Earth. |
| To Start UTM Zone | Unitless | Text | The UTM Zone character indicator for the detic subpoint of the To-object at the start of the interval. Available only when the central body is Earth. |
| To Start UTM Easting | Distance | Real Number | The easting value within the UTM zone for the detic subpoint of the To-object at the start of the interval. Available only when the central body is Earth. |
| To Start UTM Northing | Distance | Real Number | The northing value within the UTM zone for the detic subpoint of the To-object at the start of the interval. Available only when the central body is Earth. |
| To Start MGRS Cell | Unitless | Text | The MGRS (Military Grid Reference System) code for the cell area containing the detic subpoint of the To-object at the start of the interval. Available only when the central body is Earth. |
| To Stop UTM Zone | Unitless | Text | The UTM Zone character indicator for the detic subpoint of the To-object at the end of the interval. Available only when the central body is Earth. |
| To Stop UTM Easting | Distance | Real Number | The easting value within the UTM zone for the detic subpoint of the To-object at the end of the interval. Available only when the central body is Earth. |
| To Stop UTM Northing | Distance | Real Number | The northing value within the UTM zone for the detic subpoint of the To-object at the end of the interval. Available only when the central body is Earth. |
| To Stop MGRS Cell | Unitless | Text | The MGRS (Military Grid Reference System) code for the cell area containing the detic subpoint of the To-object at the end of the interval. Available only when the central body is Earth. |