Reports information concerning the start
and stop time of each access interval.
Name |
Dimension |
Type |
Description |
Access Number |
Unitless |
Integer |
A count of the intervals. |
Start Time |
DateFormat |
Real Number |
Start time of an interval. |
Stop Time |
DateFormat |
Real Number |
Stop time of an interval. |
Duration |
TimeUnit |
Real Number |
The duration of the interval. |
From Pass Number |
Unitless |
Text |
The pass number of the From-object at the start of
the interval. If the object does not support the computation of
passes, then the value will be "N/A". |
To Pass Number |
Unitless |
Text |
The pass number of the To-object at the start of
the interval. If the object does not support the computation of
passes, then the value will be "N/A". |
From Start Lat |
LatitudeUnit |
Real Number |
The detic latitude of the From-object at the start
of the interval. |
From Start Lon |
LongitudeUnit |
Real Number |
The detic longitude of the From-object at the start
of the interval. |
From Start Alt |
DistanceUnit |
Real Number |
The detic altitude of the From-object at the start
of the interval. |
From Stop Lat |
LatitudeUnit |
Real Number |
The detic latitude of the From-object at the end of
the interval. |
From Stop Lon |
LongitudeUnit |
Real Number |
The detic longitude of the From-object at the end
of the interval. |
From Stop Alt |
DistanceUnit |
Real Number |
The detic altitude of the From-object at the end of
the interval. |
To Start Lat |
LatitudeUnit |
Real Number |
The detic latitude of the To-object at the start of
the interval. |
To Start Lon |
LongitudeUnit |
Real Number |
The detic longitude of the To-object at the start
of the interval. |
To Start Alt |
DistanceUnit |
Real Number |
The detic altitude of the To-object at the start of
the interval. |
To Stop Lat |
LatitudeUnit |
Real Number |
The detic latitude of the To-object at the end of
the interval. |
To Stop Lon |
LongitudeUnit |
Real Number |
The detic longitude of the To-object at the end of
the interval. |
To Stop Alt |
DistanceUnit |
Real Number |
The detic altitude of the To-object at the end of
the interval. |
Start Constraint |
Unitless |
Text |
The access constraint that determined the start
time of the data. |
Stop Constraint |
Unitless |
Text |
The access constraint that determined the stop time
of the data. |
From Pass
Number End |
Unitless |
Text |
The pass number of the From-object at the end of
the interval. If the object does not support the computation of
passes, then the value will be "N/A". |
To Pass Number
End |
Unitless |
Text |
The pass number of the To-object at the end of the
interval. If the object does not support the computation of passes,
then the value will be "N/A". |
To Object |
Unitless |
Text |
The class name and name of the To-object. |
From Object |
Unitless |
Text |
The class name and name of the From-object. |
To Parent |
Unitless |
Text |
The name of the parent of the To-object. If the
object has no parent (other than the Scenario), then the value will
be "No Parent". |
From Parent |
Unitless |
Text |
The name of the parent of the From-object. If the
object has no parent (other than the Scenario), then the value will
be "No Parent". |
From Precision Pass Number |
Unitless |
Real Number or Text |
The precision pass number of the From-object at the
start of the interval. If the object does not support the
computation of passes, then the value will be "N/A". |
To
Precision Pass Number |
Unitless |
Real Number or Text |
The precision pass number of the To-object at the
start of the interval. If the object does not support the
computation of passes, then the value will be "N/A". |
From Precision Pass Number
End |
Unitless |
Real Number or Text |
The precision pass number of the From-object at the
end of the interval. If the object does not support the computation
of passes, then the value will be "N/A". |
To Precision Pass Number
End |
Unitless |
Real Number or Text |
The precision pass number of the To-object at the
end of the interval. If the object does not support the computation
of passes, then the value will be "N/A". |
From Path Number |
Unitless |
Text |
The path number of the From-object at the start of
the interval. If the object does not support the computation of
passes, then the value will be "N/A". |
To Path Number |
Unitless |
Text |
The path number of the To-object at the start of
the interval. If the object does not support the computation of
passes, then the value will be "N/A". |
From Path
Number End |
Unitless |
Text |
The path number of the From-object at the end of
the interval. If the object does not support the computation of
passes, then the value will be "N/A". |
To Path Number
End |
Unitless |
Text |
The path number of the To-object at the end of the
interval. If the object does not support the computation of passes,
then the value will be "N/A". |
From Precision Path Number |
Unitless |
Real Number or Text |
The precision path number of the From-object at the
start of the interval. If the object does not support the
computation of passes, then the value will be "N/A". |
To
Precision Path Number |
Unitless |
Real Number or Text |
The precision path number of the To-object at the
start of the interval. If the object does not support the
computation of passes, then the value will be "N/A". |
From Precision Path Number
End |
Unitless |
Real Number or Text |
The precision path number of the From-object at the
end of the interval. If the object does not support the computation
of passes, then the value will be "N/A". |
To Precision Path Number
End |
Unitless |
Real Number or Text |
The precision path number of the To-object at the
end of the interval. If the object does not support the computation
of passes, then the value will be "N/A". |
Start Constraint Definition |
Unitless |
Text |
Reports out constraint-dependent parameters, if
applicable, for the start constraint; otherwise, not
applicable. |
Stop Constraint Definition |
Unitless |
Text |
Reports out constraint-dependent parameters, if
applicable, for the stop constraint; otherwise, not
applicable. |
From Precision Pass Number
Mid |
Unitless |
Real Number or Text |
The precision pass number of the From-object at the
mid-time of the interval. If the object does not support the
computation of passes, then the value will be "N/A". |
To Precision Pass Number
Mid |
Unitless |
Real Number or Text |
The precision pass number of the To-object at the
mid-time of the interval. If the object does not support the
computation of passes, then the value will be "N/A". |
From Start UTM
Zone |
Unitless |
Text |
The UTM Zone character indicator for the detic
subpoint of the From-object at the start of the interval. Available
only when the central body is Earth. |
From Start
UTM Easting |
DistanceUnit |
Real Number |
The easting value within the UTM zone for the detic
subpoint of the From-object at the start of the interval. Available
only when the central body is Earth. |
From
Start UTM Northing |
DistanceUnit |
Real Number |
The northing value within the UTM zone for the
detic subpoint of the From-object at the start of the interval.
Available only when the central body is Earth. |
From Start
MGRS Cell |
Unitless |
Text |
The MGRS (Military Grid Reference System) code for
the cell area containing the detic subpoint of the From-object at
the start of the interval. Available only when the central body is
Earth. |
From Stop UTM
Zone |
Unitless |
Text |
The UTM Zone character indicator for the detic
subpoint of the From-object at the end of the interval. Available
only when the central body is Earth. |
From Stop
UTM Easting |
DistanceUnit |
Real Number |
The easting value within the UTM zone for the detic
subpoint of the From-object at the end of the interval. Available
only when the central body is Earth. |
From Stop
UTM Northing |
DistanceUnit |
Real Number |
The northing value within the UTM zone for the
detic subpoint of the From-object at the end of the interval.
Available only when the central body is Earth. |
From Stop MGRS
Cell |
Unitless |
Text |
The MGRS (Military Grid Reference System) code for
the cell area containing the detic subpoint of the From-object at
the end of the interval. Available only when the central body is
Earth. |
To Start UTM
Zone |
Unitless |
Text |
The UTM Zone character indicator for the detic
subpoint of the To-object at the start of the interval. Available
only when the central body is Earth. |
To Start UTM
Easting |
DistanceUnit |
Real Number |
The easting value within the UTM zone for the detic
subpoint of the To-object at the start of the interval. Available
only when the central body is Earth. |
To Start UTM
Northing |
DistanceUnit |
Real Number |
The northing value within the UTM zone for the
detic subpoint of the To-object at the start of the interval.
Available only when the central body is Earth. |
To Start MGRS
Cell |
Unitless |
Text |
The MGRS (Military Grid Reference System) code for
the cell area containing the detic subpoint of the To-object at the
start of the interval. Available only when the central body is
Earth. |
To Stop UTM Zone |
Unitless |
Text |
The UTM Zone character indicator for the detic
subpoint of the To-object at the end of the interval. Available
only when the central body is Earth. |
To Stop UTM
Easting |
DistanceUnit |
Real Number |
The easting value within the UTM zone for the detic
subpoint of the To-object at the end of the interval. Available
only when the central body is Earth. |
To Stop UTM
Northing |
DistanceUnit |
Real Number |
The northing value within the UTM zone for the
detic subpoint of the To-object at the end of the interval.
Available only when the central body is Earth. |
To Stop MGRS
Cell |
Unitless |
Text |
The MGRS (Military Grid Reference System) code for
the cell area containing the detic subpoint of the To-object at the
end of the interval. Available only when the central body is
Earth. |