Chain: Access Data

Reports certain data, computed via the Access Tool, for a chain consisting of only two objects. The 'From-object' is the first object listed in the strand; the 'To-object' is the second object listed. Values are reported for each strand access interval that lies within the requested report intervals.

Type: Interval data. Intended to be used only with elements from this same data provider.

Availability: Reports | Graphs

Name Dimension Type Description
Start Time DateFormat Real Number The start time of an interval.
Stop Time DateFormat Real Number The stop time of an interval.
Duration TimeUnit Real Number The duration of the interval.
From Pass Number Unitless Text The pass number of the From-object at the start of the interval. If the object does not support the computation of passes, then the value will be "N/A".
To Pass Number Unitless Text The pass number of the To-object at the start of the interval. If the object does not support the computation of passes, then the value will be "N/A".
From Start Lat LatitudeUnit Real Number The detic latitude of the From-object at the start of the interval.
From Start Lon LongitudeUnit Real Number The detic longitude of the From-object at the start of the interval.
From Start Alt DistanceUnit Real Number The detic altitude of the From-object at the start of the interval.
From Stop Lat LatitudeUnit Real Number The detic latitude of the From-object at the end of the interval.
From Stop Lon LongitudeUnit Real Number The detic longitude of the From-object at the end of the interval.
From Stop Alt DistanceUnit Real Number The detic altitude of the From-object at the end of the interval.
To Start Lat LatitudeUnit Real Number The detic latitude of the To-object at the start of the interval.
To Start Lon LongitudeUnit Real Number The detic longitude of the To-object at the start of the interval.
To Start Alt DistanceUnit Real Number The detic altitude of the To-object at the start of the interval.
To Stop Lat LatitudeUnit Real Number The detic latitude of the To-object at the end of the interval.
To Stop Lon LongitudeUnit Real Number The detic longitude of the To-object at the end of the interval.
To Stop Alt DistanceUnit Real Number The detic altitude of the To-object at the end of the interval.
From Pass Number End Unitless Text The pass number of the From-object at the end of the interval. If the object does not support the computation of passes, then the value will be "N/A".
To Pass Number End Unitless Text The pass number of the To-object at the end of the interval. If the object does not support the computation of passes, then the value will be "N/A".
To Object Unitless Text The class name and name of the To-object.
From Object Unitless Text The class name and name of the From-object.
To Parent Unitless Text The name of the parent of the To-object. If the object has no parent (other than the Scenario), then the value will be "No Parent".
From Parent Unitless Text The name of the parent of the From-object. If the object has no parent (other than the Scenario), then the value will be "No Parent".
From Precision Pass Number Unitless Real Number or Text The precision pass number of the From-object at the start of the interval. If the object does not support the computation of passes, then the value will be "N/A".
To Precision Pass Number Unitless Real Number or Text The precision pass number of the To-object at the start of the interval. If the object does not support the computation of passes, then the value will be "N/A".
From Precision Pass Number End Unitless Real Number or Text The precision pass number of the From-object at the end of the interval. If the object does not support the computation of passes, then the value will be "N/A".
To Precision Pass Number End Unitless Real Number or Text The precision pass number of the To-object at the end of the interval. If the object does not support the computation of passes, then the value will be "N/A".
From Path Number Unitless Text The path number of the From-object at the start of the interval. If the object does not support the computation of passes, then the value will be "N/A".
To Path Number Unitless Text The path number of the To-object at the start of the interval. If the object does not support the computation of passes, then the value will be "N/A".
From Path Number End Unitless Text The path number of the From-object at the end of the interval. If the object does not support the computation of passes, then the value will be "N/A".
To Path Number End Unitless Text The path number of the To-object at the end of the interval. If the object does not support the computation of passes, then the value will be "N/A".
From Precision Path Number Unitless Real Number or Text The precision path number of the From-object at the start of the interval. If the object does not support the computation of passes, then the value will be "N/A".
To Precision Path Number Unitless Real Number or Text The precision path number of the To-object at the start of the interval. If the object does not support the computation of passes, then the value will be "N/A".
From Precision Path Number End Unitless Real Number or Text The precision path number of the From-object at the end of the interval. If the object does not support the computation of passes, then the value will be "N/A".
To Precision Path Number End Unitless Real Number or Text The precision path number of the To-object at the end of the interval. If the object does not support the computation of passes, then the value will be "N/A".
From Precision Pass Number Mid Unitless Real Number or Text The precision pass number of the From-object at the mid-time of the interval. If the object does not support the computation of passes, then the value will be "N/A".
To Precision Pass Number Mid Unitless Real Number or Text The precision pass number of the To-object at the mid-time of the interval. If the object does not support the computation of passes, then the value will be "N/A".
From Start UTM Zone Unitless Text The UTM Zone character indicator for the detic subpoint of the From-object at the start of the interval. Available only when the central body is Earth.
From Start UTM Easting DistanceUnit Real Number The easting value within the UTM zone for the detic subpoint of the From-object at the start of the interval. Available only when the central body is Earth.
From Start UTM Northing DistanceUnit Real Number The northing value within the UTM zone for the detic subpoint of the From-object at the start of the interval. Available only when the central body is Earth.
From Start MGRS Cell Unitless Text The MGRS (Military Grid Reference System) code for the cell area containing the detic subpoint of the From-object at the start of the interval. Available only when the central body is Earth.
From Stop UTM Zone Unitless Text The UTM Zone character indicator for the detic subpoint of the From-object at the end of the interval. Available only when the central body is Earth.
From Stop UTM Easting DistanceUnit Real Number The easting value within the UTM zone for the detic subpoint of the From-object at the end of the interval. Available only when the central body is Earth.
From Stop UTM Northing DistanceUnit Real Number The northing value within the UTM zone for the detic subpoint of the From-object at the end of the interval. Available only when the central body is Earth.
From Stop MGRS Cell Unitless Text The MGRS (Military Grid Reference System) code for the cell area containing the detic subpoint of the From-object at the end of the interval. Available only when the central body is Earth.
To Start UTM Zone Unitless Text The UTM Zone character indicator for the detic subpoint of the To-object at the start of the interval. Available only when the central body is Earth.
To Start UTM Easting DistanceUnit Real Number The easting value within the UTM zone for the detic subpoint of the To-object at the start of the interval. Available only when the central body is Earth.
To Start UTM Northing DistanceUnit Real Number The northing value within the UTM zone for the detic subpoint of the To-object at the start of the interval. Available only when the central body is Earth.
To Start MGRS Cell Unitless Text The MGRS (Military Grid Reference System) code for the cell area containing the detic subpoint of the To-object at the start of the interval. Available only when the central body is Earth.
To Stop UTM Zone Unitless Text The UTM Zone character indicator for the detic subpoint of the To-object at the end of the interval. Available only when the central body is Earth.
To Stop UTM Easting DistanceUnit Real Number The easting value within the UTM zone for the detic subpoint of the To-object at the end of the interval. Available only when the central body is Earth.
To Stop UTM Northing DistanceUnit Real Number The northing value within the UTM zone for the detic subpoint of the To-object at the end of the interval. Available only when the central body is Earth.
To Stop MGRS Cell Unitless Text The MGRS (Military Grid Reference System) code for the cell area containing the detic subpoint of the To-object at the end of the interval. Available only when the central body is Earth.

STK Programming Interface 11.0.1