Data Provider Elements

SEET Radiation Dose Depth

Computes the radiation dose over the requested time interval(s), using the step size to perform the numerical integration of dose rate with time. Valid for vehicles whose central body is earth.


Available for these objects: LaunchVehicle, Missile, Satellite

Type: Time-varying data. Intended to be used only with elements from this same data provider.

Availability: Reports | Graphs

Data Provider Elements

NameDimensionTypeDescription
Shielding thicknessRadiationShieldThicknessReal NumberThe shielding thickness at which the dose was computed.
Electron doseRadiationDoseReal NumberThe accumulated radiation dose due to electrons for the shielding thickness indicated, at the given time. Valid when using NASA or CRRES models.
Electron-Bremsstrahlung doseRadiationDoseReal NumberThe accumulated radiation dose due to Bremsstrahlung electrons, at the given time. Valid when using NASA or CRRES models.
Proton doseRadiationDoseReal NumberThe accumulated radiation dose due to protons for the shielding thickness indicated, at the given time. Valid when using NASA or CRRES models.
Combined doseRadiationDoseReal NumberThe accumulated total radiation dose from all constituents, at the given time.