Data Provider Groups | Data Provider Elements

Probability Density Function

Probability density function is the probability that a parameter is equal to a particular value. It's the derivative of the cumulative density function.

For a given parameter, this report provides each value, the number of samples that have this value, the percentage (i.e. probability mentioned above) and a log of the percentage.



Available for these objects: CommSystem

Type: Fixed data given specified evaluation intervals and step sizes.

Availability: Reports | Graphs

Pre-data required: "<TruncObjectPath>" - e.g. "Satellite/Sat1/Receiver/Receiver1"

Data Provider Groups

NameDescription
Rcvd. Iso. PowerReceived isotropic power is the power at the receiver before the pre-receive gains/losses and the receiver antenna gain added (in dBW). It is equal to the EIRP with all the channel losses as well as the bandwidth overlap applied.
Flux DensityThe power from the desired transmitter crossing a unit area normal to the direction of wave propagation.
Rcvr GainReceiver Gain is the antenna gain (in dBi) of the receiver which is dependent on the antenna type used.
TequivalentThe equivalent system temperature (in K) is specified by the user as a constant value or computed at each time step from the receiver system temperature parameters defined by the user.
g/TG/T = (Receiver Gain)/(System Temperature at the Receiver). The ratio of the receive antenna gain G to the total system temperature T is the "figure of merit" for the receiver (in dB/K). The figure of merit is independent of the point where it is calculated. However, the gain and system temperature must be specified at the same point.
C/NoThe carrier to noise density ratio (C/No) where C is the carrier power and No = kT (Boltzmann's constant x system temperature) is the noise density. It is equivalent to C/N with a normalized Bandwidth (B=1).
C/(No+Io)The carrier to (noise + interference) ratio (C/(No+Io)) where C is the carrier power, No = kT (Boltzmann's constant * system temperature) and Io = interference power spectral density.
C/NThe carrier to noise ratio (C/N) where C is the carrier power and N = kTB (Boltzmann's constant x system temperature x bandwidth) is the noise power.
C/(N+I)The carrier to (noise + interference) ratio (C/(N+I)) where C is the carrier power, N = kTB (Boltzmann's constant * system temperature * bandwidth) and I = interference power.
Eb/NoThe energy per bit to noise ratio (Eb/No) where Eb is the energy per bit and No = kT (Boltzmann's constant * system temperature).
Eb/(No+Io)The energy per bit to (noise + interference) ratio (Eb/(No+Io)) where Eb is the energy per bit, No = kT (Boltzmann's constant * system temperature) and Io = interference power spectral density.
C/IC/I is the carrier power from the desired signal over the sum of all interferer powers.
Delta T/TThe ratio of interference power spectral density Io and receiver noise spectral density No.
Pwr Flux DensityThe power crossing a unit area normal to the direction of wave propagation in watts per square meter (W/m^2).
Spectral Flux DensityThe dimensions are watts/(m^2 * Hz). The power is computed across the receiver's bandwidth (as seen by the receiver's RF front end). The bandwidth is the receiver's total bandwidth.

Data Provider Elements

NameDimensionTypeDescription
ValueUnitlessReal NumberConstraint specific defining parameters. Active Constraint values are the actual, user-defined values. Example: Lighting condition constraints will list the required illumination state.
No. SamplesUnitlessIntegerThis is the number of samples of each parameter value used in computing the PDF or CDF for the CommSystem parameters.
PercentageUnitlessReal NumberThis is the percentage of occurrence (PDF) or cumulative percentage of occurrence (CDF) for each CommSystem parameter value.
Log PercentUnitlessReal NumberThis is the log based 10 of the percentage of occurrence (PDF) or cumulative percentage of occurrence (CDF) for each CommSystem parameter value.