SEET Radiation (Vehicle)
Specify SEET vehicle radiation options.
Syntax
SEET <VehiclePath> Radiation {RadOptions}
Related commands
Description
This command is valid for Satellite, Missile & Launch Vehicle.
The following table describes the options available for setting vehicle radiation parameters.
{RadOptions} | Description |
---|---|
ApSource {StaticValue | UseFluxFile} | Specify the manner in which the Ap (geomagnetic flux index) is obtained. |
Ap <Value> | When ApSource is StaticValue, enter a <Value> between 0.0 and 400.0 for Ap. |
FluxFile "<Filepath>" | When ApSource is UseFluxFile, enter the name of the flux file. |
CompMode {APEXRAD | CRRESRAD | NASA | IRENE | CRRES | RadOnly} | Enter the Radiation model to use for computations. |
DoseChannel {Total | LowLET | HighLET} | Enter the dose channel value. |
DoseIntegrationStep <Step> | Specifies the time step for sampling (of dose rate from raditation-dose databases, or of fluence versus energy from the flux-model databases) that goes into dose computations. |
DoseReportStep <Step> | Specify the default time step used by data providers reporting radiation-dose output. When graphing or reporting from the Report & Graph Manager Page, this value can be overridden by specifying Step Size under Time Properties. |
UseNuclearAttenuation {Yes | No} | Specify the use of nuclear attenuation. |
IncludeNucAttenNeutrons {Yes | No} | Specify the inclusion of neutrons in the nuclear attenuation model. |
DetectorGeometry {SemiInfiniteSlab | FiniteSlab | Spherical} | Models the geometry of the detector. |
DetectorType {Detector} | Enter the material of the detector.
Valid values for {Detector} are Aluminum, Graphite, Silicon, Air, Bone, Calcium, Gallium, Lithium, SiliconDioxide, Tissue, Water CRRESRAD, APEXRAD, and Radonly computational modes only support Silicon. |
ClearThicknesses | Remove all shielding thickness values. However, since at least one must be specified, it is expected that an AddThickness option will follow this option in the connect command. |
AddThickness <Value> | Enter a <Value> (in Mils) to add a specific shielding thickness. |
RemoveThickness <Value> | Enter the shielding thickness value (in Mils); the thickness will be removed, if present. |
UseModelEpoch {Yes | No} | Enter Yes to set the magnetic field to use the model's reference epoch. |
ShiftSAA {Yes | No} | Enter Yes to shift the SAA accordingly, when UseModelEpoch is set to Yes. |
ClearThicknesses, AddThickness and RemoveThickness options are only valid if CompMode is CRRES or NASA, as the other modes have fixed shielding thickness lists.
The following table describes the shielding thickness values based on computational mode.
CompMode | Shielding Thickness |
---|---|
APEXRAD | 4.29 Mils, 82.5 Mils, 232.5 Mils, 457.5 Mils |
CRRESRAD | 82.5 Mils, 232.5 Mils, 457.5 Mils, 886.5 Mils |
CRRES | User defined |
NASA | User defined |
RadOnly | 82.5 Mils, 232.5 Mils, 457.5 Mils |
Examples
To set radiation parameters for Satellite1:
To set radiation Computation Mode to NASAIRENE for Satellite1:
Return message
Group membership
This command belongs to the following group(s):
Version
10