IAgSnEOIRBand Interface for defining the
individual band properties.
BandName |
The name of the band. |
DynamicRange |
The ratio of the brightest signal to the noise floor. |
DynamicRangeMode |
Unlimited allowing pixels to measure any amount of radiant signal without limit or Simulate Saturation where pixels can only measure up to the specified saturation level of radiant signal. |
EffFocalL |
The effective focal length of the current sensor band. |
EntrancePDia |
Diameter of the single lens equivalent optical prescription. |
Fnumber |
The F-Number ratio of the system, the effective focal length divided by the clear aperture diameter for this sensor band. |
HighBandEdgeWL |
The cut-off spectral wavelength of the current sensor band. |
HorizontalHalfAngle |
Half the horizontal angular extent of the rectangular EOIR sensor bands field-of-view. |
HorizontalIFOV |
The horizontal angular extent of a single individual pixels field-of-view for this sensor band. |
HorizontalPixels |
The number of pixels or samples distributed evenly across the horizontal dimension of the rectangular EOIR sensor bands focal plane. |
HorizontalPP |
The spacing between pixels or samples along the horizontal dimension of the rectangular EOIR sensor bands focal plane. |
ImageQuality |
Discrete level of optical image quality. Aberrations are modeled based on a RMS wavefront error. |
IntegrationTime |
The time interval over which radiant signal is collected before generating an image. |
LongDFocus |
The amount of defocus along the optical axis between the ideal image focal plane and the actual detector focal plane for the current sensor band. |
LowBandEdgeWL |
The cut-on spectral wavelength of the current sensor band. |
NEI |
Noise equivalent irradiance or radiance for the current sensor band. |
NumIntervals |
The number of oversampled spectral intervals to discretely simulate for this sensor band. |
RenderBand |
Band render flag |
SaturationMode |
The radiant energy units for saturation and sensitivity, Irradiance better suited for observing point sources or Radiance better suited for resolved images. |
Saturations |
Get the collection of Saturation time-value pairs. |
SEI |
Saturation equivalent irradiance or radiance for the current sensor band. |
Sensitivities |
Get the collection of Sensitivity time-value pairs. |
VerticalHalfAngle |
Half the vertical angular extent of the rectangular EOIR sensor bands field-of-view. |
VerticalIFOV |
The vertical angular extent of a single individual pixels field-of-view for this sensor band. |
VerticalPixels |
The number of pixels or samples distributed evenly across the vertical dimension of the rectangular EOIR sensor bands focal plane. |
VerticalPP |
The spacing between pixels or samples along the vertical dimension of the rectangular EOIR sensor bands focal plane. |
Wavelength |
The wavelength in the sensors spectral band to use for diffraction modeling calculations. |
WavelengthType |
The relative position within the sensors spectral band to use as the reference wavelength for diffraction modeling calculations. |


~266.gif)