Specify SEET radiation options.
SEET <ScenarioPath> Radiation {RadOptions}
The following table describes the options available for setting Scenario radiation parameters.
{RadOptions} | Description |
---|---|
CrresProtonActivity {Quiet | Active} | Specify the CRRES proton activity. |
CrresRadiationActivity {Quiet | Active | Average} | Specify the CRRES radiation activity. |
NasaActivity {SolarMin | SolarMax} | Specify the NASA model activity level. |
NASAEnergyList {UseDefault | {Electron | Proton} [Clear] {EnergyOptions}} | Specify the energy list values. The
table below describes the {EnergyOptions}.
The Clear option, if entered, removes all energy values. However, since the energy list can not be empty, at least one Add {EnergyOptions} value is expected to be found following the Clear keyword. |
The following table describes the {EnergyOptions} used with the NASAEnergyList command.
{EnergyOptions} | Description |
---|---|
Add [CRRES | <Value>] | Specify CRRES to add all CRRES energy
values.
Specify <Value> to add the specific value to the energy list. <Value> is entered in MeV. Electron energies must be between 0.04 and 7.0 MeV; proton energies must be between 0.1 and 400.0 MeV. |
Remove [CRRES | nonCRRES | <Value>] | Specify CRRES to remove all CRRES
energy values.
Specify nonCRRES to remove all energy values that are not supported by CRRES. Specify <Value> to remove a specific value from the energy list. |
To use the default NASA energy list:
SEET * Radiation NASAEnergyList UseDefault
To clear proton energies from the list and add new values:
SEET * Radiation NASAEnergyList Proton Clear Add .12 Add 2.2 Add 3.3 Add 4.4
If activated, Connect returns an acknowledgement message.
This command belongs to the following group(s):
9.1
STK Programming Interface 11.0.1