Name | Dimension | Type | Description |
---|---|---|---|
Gap Number | Unitless | Integer | Counter of the gaps between access intervals. |
Start Time | Date | Real Number or Text | Start time of an interval. |
Stop Time | Date | Real Number or Text | Stop time of an interval. |
Duration | Time | Real Number | The duration of the interval. |
From Pass Number | Unitless | Text | The pass number of the From-object at the start of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
To Pass Number | Unitless | Text | The pass number of the To-object at the start of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
From Start Lat | Latitude | Real Number or Text | The detic latitude of the From-object at the start of the interval. |
From Start Lon | Longitude | Real Number or Text | The detic longitude of the From-object at the start of the interval. |
From Start Alt | Distance | Real Number | The detic altitude of the From-object at the start of the interval. |
From Stop Lat | Latitude | Real Number or Text | The detic latitude of the From-object at the end of the interval. |
From Stop Lon | Longitude | Real Number or Text | The detic longitude of the From-object at the end of the interval. |
From Stop Alt | Distance | Real Number | The detic altitude of the From-object at the end of the interval. |
To Start Lat | Latitude | Real Number or Text | The detic latitude of the To-object at the start of the interval. |
To Start Lon | Longitude | Real Number or Text | The detic longitude of the To-object at the start of the interval. |
To Start Alt | Distance | Real Number | The detic altitude of the To-object at the start of the interval. |
To Stop Lat | Latitude | Real Number or Text | The detic latitude of the To-object at the end of the interval. |
To Stop Lon | Longitude | Real Number or Text | The detic longitude of the To-object at the end of the interval. |
To Stop Alt | Distance | Real Number | The detic altitude of the To-object at the end of the interval. |
Start Constraint | Unitless | Text | The access constraint that determined the start time of the gap. |
Stop Constraint | Unitless | Text | The access constraint that determined the stop time of the gap. |
From Pass Number End | Unitless | Text | The pass number of the From-object at the end of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
To Pass Number End | Unitless | Text | The pass number of the To-object at the end of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
To Object | Unitless | Text | The class name and name of the To-object. |
From Object | Unitless | Text | The class name and name of the From-object. |
To Parent | Unitless | Text | The name of the parent of the To-object. If the object has no parent (other than the Scenario), then the value will be "No Parent". |
From Parent | Unitless | Text | The name of the parent of the From-object. If the object has no parent (other than the Scenario), then the value will be "No Parent". |
From Precision Pass Number | Unitless | Real Number or Text | The precision pass number of the From-object at the start of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
To Precision Pass Number | Unitless | Real Number or Text | The precision pass number of the To-object at the start of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
From Precision Pass Number End | Unitless | Real Number or Text | The precision pass number of the From-object at the end of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
To Precision Pass Number End | Unitless | Real Number or Text | The precision pass number of the To-object at the end of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
From Path Number | Unitless | Text | The path number of the From-object at the start of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
To Path Number | Unitless | Text | The path number of the To-object at the start of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
From Path Number End | Unitless | Text | The path number of the From-object at the end of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
To Path Number End | Unitless | Text | The path number of the To-object at the end of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
From Precision Path Number | Unitless | Real Number or Text | The precision path number of the From-object at the start of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
To Precision Path Number | Unitless | Real Number or Text | The precision path number of the To-object at the start of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
From Precision Path Number End | Unitless | Real Number or Text | The precision path number of the From-object at the end of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
To Precision Path Number End | Unitless | Real Number or Text | The precision path number of the To-object at the end of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
Start Constraint Definition | Unitless | Text | Reports out constraint-dependent parameters, if applicable, for the start constraint; otherwise, not applicable. |
Stop Constraint Definition | Unitless | Text | Reports out constraint-dependent parameters, if applicable, for the stop constraint; otherwise, not applicable. |
Start Constraint Definition with Units | Unitless | Text | Reports out constraint-dependent parameters, if applicable, for the start constraint, where the units for values are indicated; otherwise, not applicable. |
Stop Constraint Definition with Units | Unitless | Text | Reports out constraint-dependent parameters, if applicable, for the stop constraint, where the units for values are indicated; otherwise, not applicable. |
From Precision Pass Number Mid | Unitless | Real Number or Text | The precision pass number of the From-object at the mid-time of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
To Precision Pass Number Mid | Unitless | Real Number or Text | The precision pass number of the To-object at the mid-time of the interval. If the object does not support the computation of passes, then the value will be "N/A". |
From Start UTM Zone | Unitless | Text | The UTM Zone character indicator for the detic subpoint of the From-object at the start of the interval. Available only when the central body is Earth. |
From Start UTM Easting | Distance | Real Number | The easting value within the UTM zone for the detic subpoint of the From-object at the start of the interval. Available only when the central body is Earth. |
From Start UTM Northing | Distance | Real Number | The northing value within the UTM zone for the detic subpoint of the From-object at the start of the interval. Available only when the central body is Earth. |
From Start MGRS Cell | Unitless | Text | The MGRS (Military Grid Reference System) code for the cell area containing the detic subpoint of the From-object at the start of the interval. Available only when the central body is Earth. |
From Stop UTM Zone | Unitless | Text | The UTM Zone character indicator for the detic subpoint of the From-object at the end of the interval. Available only when the central body is Earth. |
From Stop UTM Easting | Distance | Real Number | The easting value within the UTM zone for the detic subpoint of the From-object at the end of the interval. Available only when the central body is Earth. |
From Stop UTM Northing | Distance | Real Number | The northing value within the UTM zone for the detic subpoint of the From-object at the end of the interval. Available only when the central body is Earth. |
From Stop MGRS Cell | Unitless | Text | The MGRS (Military Grid Reference System) code for the cell area containing the detic subpoint of the From-object at the end of the interval. Available only when the central body is Earth. |
To Start UTM Zone | Unitless | Text | The UTM Zone character indicator for the detic subpoint of the To-object at the start of the interval. Available only when the central body is Earth. |
To Start UTM Easting | Distance | Real Number | The easting value within the UTM zone for the detic subpoint of the To-object at the start of the interval. Available only when the central body is Earth. |
To Start UTM Northing | Distance | Real Number | The northing value within the UTM zone for the detic subpoint of the To-object at the start of the interval. Available only when the central body is Earth. |
To Start MGRS Cell | Unitless | Text | The MGRS (Military Grid Reference System) code for the cell area containing the detic subpoint of the To-object at the start of the interval. Available only when the central body is Earth. |
To Stop UTM Zone | Unitless | Text | The UTM Zone character indicator for the detic subpoint of the To-object at the end of the interval. Available only when the central body is Earth. |
To Stop UTM Easting | Distance | Real Number | The easting value within the UTM zone for the detic subpoint of the To-object at the end of the interval. Available only when the central body is Earth. |
To Stop UTM Northing | Distance | Real Number | The northing value within the UTM zone for the detic subpoint of the To-object at the end of the interval. Available only when the central body is Earth. |
To Stop MGRS Cell | Unitless | Text | The MGRS (Military Grid Reference System) code for the cell area containing the detic subpoint of the To-object at the end of the interval. Available only when the central body is Earth. |