Control the amount of data stored for an articulation (data thinning)
VO <ObjectPath> PruneArtic {PruneOption}
The VO PruneArtic command allows you to control the amount of data being kept by the system for an articulation when receiving it via Connect.
Valid values for {PruneOption} are:
{Type} | Description |
---|---|
Before {TimeValue} | Remove all articulation data for the object before the specified time. For valid {TimeValue} values see Time Options. |
All | Remove all articulation data for the object. |
To prune articulation data for the ERS1 satellite prior to July 1, 1998 at 3 am:
VO */Satellite/ERS1 PruneArtic Before "1 Jul 1998 03:00:00.00"
If activated, Connect returns an acknowledgement message.
This command belongs to the following group(s):
10
STK Programming Interface 11.0.1